Product Detailed
Loop Calibrator 717 1,OEM Loop Calibrator 2,Advanced Loop Calibrator 3,Large display loop calibrator 4.Fluke Loop calibrator

 Loop Calibrator series 1

Loop Calibrator series 2

Loop Calibrator-YHS717

Features of Loop Calibrator 

The fast, one-handed tool for loop checks. Just click to calibrate.

This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:

Large display and simple, quick-click interface for easy one-handed operation.mA accuracy of 0.025%, superior to other loop calibrators in this price range.Simultaneous mA and % readout for quick, easy interpretation of readings.1 µA resolution for mA source, simulate and measure.Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests. 0-100% ‘span check’ for fast confirmation of zero and span. 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.Measures V dc to 28 V.Single 9V battery that is easily changed without braking calibration sealPush button 25% steps for fast, easy linearity checks.0 - 20 mA or 4 - 20 mA default start up modes.Innovative output adjustment dial with 1 µA and 100 resolution.Specifications of Loop Calibrator

Current Measurement

Range:

0 to 24 mA

Resolution:

0.001 mA

Accuracy:

0.025% Rdg + 2 LSD

Current Sourcing

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.025% Rdg + 2 LSD

Drive Capability:

1200 Ω; 950 Ω at 20 mA in HART mode

Current Simulation

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.025% Rdg + 2 LSD

Ext. loop voltage requirement:

12-30 V

Loop Power

While measuring mA, 24 V

Voltage measurement

Range:

0 to 28 V DC

Resolution:

1 mV

Accuracy:

0.025% Rdg + 2 LSD

Environmental Specifications

Operating Temperature -10ºC to 55ºC

Storage Temperature -30ºC to 60ºC

Humidity (Without Condensation) 0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)

Temperature Coefficient -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC